GB7
CLEANING
WARNING:
- Do not use steam cleaners.
- Disconnect the appliance from the power supply
IMPORTANT: Do not use corrosive or abrasive detergents. If any of these products accidentally comes into contact with the appliance, clean it
immediately with a damp cloth.
• Clean the surfaces with a damp cloth. If very dirty, add a few drops of washing up detergent to the water. Dry with a dry cloth.
IMPORTANT: Do not use abrasive sponges or metallic scrapers or scouring pads. Their use could eventually ruin the enamelled surfaces.
• Use specic detergents to clean the appliance and follow the manufacturer’s instructions
IMPORTANT: Clean the lters at least once a month to remove built-up oil and grease.
INSTALLATION - FITTING INSTRUCTIONS
Note: the elements marked with the symbol “(*)” are optional accessories supplied only with some models or elements to purchase, not supplied.
Extraction version installation (A): Fumes are extracted and expelled to the outside through an exhaust duct xed to the upper circular ange A1 (bayonet
coupling + screw fastening), remove the prescored metal panel and t the duct connector.
Filter version installation (F): If fumes and steam cannot be discharged to the outside, the hood can be used in lter version by tting a carbon lter/s (*);
fumes and steam are recycled through the front grille located above the control panel (do not remove the pre-scored metal panels!).
Check the position of the extraction/lter selector (inside the hood) G.
Wall xing - Place the hood against the wall (or use the template H, if provided) and mark the holes (3 or 4 Ø 8 mm holes) with a pencil, drill, insert the wall plugs J
in the holes and 2 screws K in the top holes, remove the grille and hook the hood on the 2 screws, then insert the third (and fourth) screw/s L from inside and tighten
all of them.
Fixing to wall unit - Position the hood (or use the template H, if provided) and, using a pencil, mark the 4 Ø 6 mm through holes to be made on the bottom of the
wall unit.
Fix the hood with 4 screws M from inside the wall unit.
DESCRIPTION AND USE OF THE HOOD
Control panel
Light: move the switch to the right or press the next button to switch on.
Extraction speed: Move the switch to the right or press the next button to increase extraction speed.
Note: You should open the visor N every time you switch on the hood in order to use it correctly.
Grease lter - can be one of the following types:
Paper lter: to be replaced once a month or, if the top part is coloured, when the colour shows through the holes in the grille.
Metal lter: to be washed once a month by hand or in a dishwasher with quick wash cycle at low temperature.
To access the grease lters open the grille by means of the releases E1 and free it from the retainers R1.
The carbon lter (*) must be changed once a month.
Attention! The metal lter may become opaque over time; this does not aect its ltering capacity.
Replacing lamp/s - Remove the grille and the lamp to be replaced. Ret the grille.
Lamp
Power
(W)
Socket
Voltage
(V)
Dimension
(mm)
ILCOS D Code
(according IEC
61231)
28 E14 230
67
(Light Center
Length)
HSGSB/C/UB-28-
230-E14-67