ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the
knob and proceed as follows:
tighten screw to reduce the flame height (-)
loosen screw to increase the flame height (+)
The adjustment must be performed with the tap in minimum gas
setting position (small flame) .
The primary air of the burners does not need to be adjusted.
At this stage, light up the burners and turn the knobs from max
position to minimum position to check flame stability.
Upon completion of adjustment, reseal using sealing wax or an
equivalent material.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the height “B” must
be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height
“B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions which specify the
correct distance. In case of installation of an oven under the cooktop, please refer to the separate
oven instructions.
INJECTORS TABLE
CATEGORY II2H3+
ELECTRIC SUPPLY: 230V ~ 50Hz
Ty p e o f g a s u s e d Ty p e o f
burner
Injector
marking
Rated heat
capacity kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure
(
mbar)
min. rat. max.
NATURAL GAS
(Methane)
G20
rapid
semirapid
auxiliary
Y 115
H2 98
X 72
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
LIQUID PETROLEUM
GAS
(Butane)
G30
rapid
semirapid
auxiliary
87
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20 28-30 35
LIQUID PETROLEUM
GAS
(Propane)
G31
rapid
semirapid
auxiliary
87
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25 37 45
Type of gas used Appliance model
4 burners
Total rated heat
capacity kW
To t a l r a t e d
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20
20 mbar 2C - 2 SR - 1 AUX 10.30 981 l/h 9.52
G30
28-30 mbar 2C - 2 SR - 1 AUX 10.30 749 g/h 30.94
G31
37 mbar 2C - 2 SR - 1 AUX 10.30 735 g/h 23.80