20
HOOD AND CABINETRY CLEARANCES (MM)
INJECTOR TABLE
CATEGORY: II2H3+
Electric Power: 230 V - 50 Hz
If a hood is to be installed above the hob, refer to the
hood installation instructions to ensure the correct height
above the hob.
Type of gas
used
Ty p e o f
burner
Injector
label
Control
primary
air (X)
(mm)
Nominal
heat
flow
kW
Nominal
consumption
Reduced
heat flow
kW
Gas pressure
(mbar)
min. nom. max.
NATURAL
GAS
(Methane)
G20
wok
fast
semi-fast
auxiliary
145
128
95
78
6
-
-
-
4,20
3,00
1,65
1,00
400 l/h
286 l/h
157 l/h
95 l/
1.40
0.90
0.40
0.30
17 20 25
LIQUID
PETROLEUM
GAS (Butane)
G30
wok
fast
semi-fast
auxiliary
100
85
65
50
11
-
-
-
4,20
3,00
1,65
1,00
305 g/h
218 g/h
120 g/h
73 g/h
1.40
0.90
0.40
0.30
25 30 35
LIQUID
PETROLEUM
GAS (Propane)
G31
wok
fast
semi-fast
auxiliary
100
85
65
50
11
-
-
-
4,20
3,00
1,65
1,00
300 g/h
214 g/h
118 g/h
71 g/h
1.40
0.90
0.40
0.30
25 30 35
Type of gas used
Configuration
model
Nominal heat
flow kW
Overall nominal
consumption
Required air (m
3
)
for the
combustion 1 m
3
of gas
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
5 burners
5 burners
5 burners
11,50
11,50
11,50
1090 l/h
836 g/h
821 g/h
9,52
30,94
23,80