HOW TO USE THE HOB
WARNING
Do not let the burner ame extend beyond the edge of the pan.
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
• Toigniteoneoftheburners,turntherelativeknobanti-clockwisetothemaximumamesetting.
• Presstheknobagainstthecontrolpaneltoignitetheburner.
• Aftertheburnerhasignited,keeptheknobpressedforabout5-10secondstoallowproperdeviceoperation.Thisburnersafetydeviceshutsoffthegassupplyto
theburneriftheamegoesoutaccidentally(becauseofsuddendraught,aninterruptioninthegasdelivery,boilingoverofliquids,etc.).
• The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit,wait at least one minute before trying
to light it again.Intheeventoftheburnersamesbeingaccidentallyextinguished,turnofftheburnercontrolanddonotattempttoreigniteitforatleastoneminute.
NOTE:shouldparticularlocalconditionsofthedeliveredgasmaketheignitionofburnerdifcult,itisadvisabletorepeattheoperationwiththeknobturnedtosmall
amesetting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this case, repeat the operations
described above.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: if the distance “A” between the wall cabinets is
between 600 mm and 730 mm, the height “B” must be a
minimum of 530 mm.
if the distance “A” between the wall cabinets is greater
than the width of the hob, the height “B” must be a
minimum of 400 mm.
In case of installation of a hood above the hob, please refe
r
to the hood instructions fot the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
kW kW min.rat. max.
NATURAL GAS
(Methane) G20
Rapid 115Y 3.00 286 l/h0.60
17 20 25Semi-rapid 95Z1.75167 l/h0.35
Auxiliary 72X1.0095 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid 85 3.00 218 g/h0.60
20 28-3035Semi-rapid 63 1.75 127 g/h0.35
Auxiliary501.0073 g/h 0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid 85 3.00 214 g/h0.60
25 37 45Semi-rapid 63 1.75 125 g/h0.35
Auxiliary501.0071 g/h 0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1 m
3
of gas
G20 20 mbar 1 R - 2 SR - 1 AUX 7.50 715 l/h9.52
G30 28-30 mbar 1 R - 2 SR - 1 AUX 7.50 545 g/h30.94
G31 37 mbar 1 R - 2 SR - 1 AUX 7.50 535 g/h23.80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz 0.6W