+3+E2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burnerInjector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity kW
Gas pressure
mbar
.xam.tar.nimRFEBWk
NATURAL GAS
(Methane) G20
Power Burner 138 A3.50333 l/h1.551.55
17 20 25
Rapid129 B3.00286 l/h0.800.60
Semi-rapid 97 1.75 167 l/h0.450.35
Auxiliary 74 B1.0095 l/h0.350.30
NATURAL GAS
(Methane) G25
Power Burner 138 A3.50388 l/h1.55
20 25 30
Rapid129 B3.00332 l/h 0.60
Semi-rapid 97 1.75 194 l/h0.35
Auxiliary 74 B1.00111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Power Burner 93 P3.50254 g/h1.55
20 28-3035
Rapid863.00 218 g/h0.60
Semi-rapid 65 1.75 127 g/h0.35
Auxiliary 50 1.00 73 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Power Burner 93 P3.50250 g/h1.55
25 37 45
Rapid863.00214 g/h0.60
Semi-rapid 65 1.75 125 g/h0.35
Auxiliary 50 1.00 71 g/h0.30
Type of gas used Model conguration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 1 PB 2C - 1 R - 2 SR - 1 AUX 11.001048 l/h9.52
G25 25 mbar 1 PB 2C - 1 R - 2 SR - 1 AUX 11.001219 l/h8.187
G30 28-30 mbar 1 PB 2C - 1 R - 2 SR - 1 AUX 11.00799 g/h30.94
G31 37 mbar 1 PB 2C - 1 R - 2 SR - 1 AUX11.00 785 g/h23.80
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Appearence of your product can be slightly different from the drawing.