P/B3SH2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Power Burner 130 B3.50333 l/h1.70
20 25 33Semi-rapid911.75167 l/h0.40
Auxiliary 68 1.00 95 l/h0.35
NATURAL GAS
G25.1
Power Burner 142 B3.50387 l/h1.55
18 25 33Semi-rapid103 1.75 194 l/h0.35
Auxiliary801.00111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Power Burner 93 P3.50254 g/h1.55
25 30 35
Semi-rapid651.75127 g/h0.35
Auxiliary501.00 73 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 25 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 762 l/h 9.52
G25.1 25 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 886 l/h 8.19
G30/31 30 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 581 g/h30.95
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Komentáře k této Příručce