ELECTRICAL CONNECTION
IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate.
ASSEMBLY
ADJUSTMENT TO DIFFERENT TYPES OF GAS
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label
on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction.
• The gas nozzles must be changed by After Sales Service or a qualified technician.
• Nozzles not supplied with the appliance must be ordered from After Sales Service.
• Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for
the replacement of the burner tap if found to be faulty.
REPLACING THE INJECTORS (see the injector table in the Instruction)
ADJUSTING MINIMUM GAS SETTING OF TAPS
REFERENCE TO LOCAL REGULATIONS
Connection to gas supply
Before connecting the appliance, make sure that the gas supply system complies with standards UNI-CIG 7129 and
UNI-CIG 7131.
Gas connection
The connection to the mains gas network or gas cylinder must be made using a rigid copper or steel pipe with fittings
complying with standards UNI-CIG 7129, or using a continuous-surface stainless steel hose complying with standards
UNI-CIG 9891.
The maximum length of the hose is 2 m.
The pressure control valves to be used must comply with the UNI EN 12864 standard for gas cylinders and the UNI EN 88
standard for piped methane gas.
REFERENCE TO LOCAL REGULATIONS
Provision for ventilation
The room in which the appliance is installed must have an air supply to current B.S. 5440 - Part 2 standards.
All rooms require a permanent vent in addition to the openable window.
If there are other fuel burning appliances in the same room B.S. 5440 - Part 2 should be consulted to determine the air vent
requirements.
If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room
volume.
Gas Safety Regulations
The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety
regulations. Failure to install appliances correctly may lead to prosecution.
It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in accordance with
the Gas Safety (Installation and Use) Regulations, the Building Regulations issued by the Department of the Environment and
the Building Standard (Scotland) (Consolidation) Regulations, issued by the Scottish Development Department.
In the G.B., CORGI registered installers work to safe standards of practice.
WARNING
This operation must be performed by a qualified technician.
WARNING
• The electrical connections must comply
with local regulations.
• The earthing of this appliance is
compulsory by law.
• Do not use an extension cord.
After having cleaned the perimeter surface,
apply the supplied gasket to the hob as shown
in the figure.
Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction.
NOTE: the power supply cable must be long enough to permit its upward extraction.
To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and
fasten them by means of their screws in accordance with the thickness of the worktop.
WARNING
This operation must be performed by a qualified technician.
L
N
Earth
(yellow/green)
A
4 x
4 x
4 x
NO
1. Remove the grates (A).
2. Remove the burner bodies (B).
3. Using a suitable wrench (C), unscrew the injector to be replaced.
4. Replace it with the injector required for the new type of gas.
5. Refit the injector in (D).
Before installing the hob, remember to apply the gas setting label supplied
with the injectors, so that it covers the information already present.
N.B.: do not place the small grates with closed arms on the WOK burner.
To ensure correct adjustment of the minimum setting, remove knob (E) and
proceed as follows:
• tighten (-) to decrease the height of the flame;
• loosen (+) to increase the height of the flame.
Adjustment must be carried out with the tap in minimum position (small
flame) .
After adjusting, reinstate the seals with sealing wax or equivalent
material.
The primary air of the burners does not need adjusting. After adjusting,
light the burners and turn the knobs from max. to min. to check flame
stability