8
Electrical connection
Electrical connections
Power supply voltage
If the hob already has a power cable, follow the
instructions given on the label attached to the cable.
Connect the appliance to the electricity supply by
means of an all-pole disconnect switch with
minimum contact gap of 3 mm.
Connecting to the terminal board
Connect the yellow/green earth wire to the terminal
with the symbol . This wire must be longer than the
other wires.
1. Remove the terminal block cover (A), undoing the
screw and inserting the cover in the terminal
block hinge (B).
2. Strip approx. 70 mm of sheath from the power
supply cable.
3. Strip approx. 10 mm of sheath from the wires.
Insert the power supply cable into the cable
clamp and connect the wires to the terminal
board as indicated in the diagram next to the
terminal board itself.
4. Secure the power cable with the cable clamp.
5. Close the cover (C) and screw it on the terminal
block with the removed screw - point (1).
Each time the cooktop is connected to the mains it
carries out an automatic check which lasts several
seconds.
WARNING
• Hob electrical connection must be made before
connecting the appliance to the electricity
supply.
• Electrical connection must be carried out in
compliance with the regulations of the local
electric utility company.
• Make sure that the voltage indicated on the
rating plate on the underside of the appliance
corresponds to the domestic power supply
voltage.
• Regulations require that the appliance is
earthed: use conductors (including the earth
conductor) of the appropriate size only.
• For electrical connection, use an H05 RR-F type
cable as specified in the table “Power supply
voltage”.
The power supply cable must be long enough to
allow the hob to be removed from the worktop. Do
not use extension leads.
Wires Amount x size
230V ~ +
3 X 4 mm
2
230-240V ~ +
3 X 4 mm
2
(Australia only)
230V 3 ~ +
4 X 1.5 mm
2
400V 3N ~ +
5 X 1.5 mm
2
400V 2N ~ +
4 x 1.5 mm
2
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
400V 3N ~
230V ~
230-240V~FOR AU ONLY
230V~FOR UK ONLY
400V 2N ~
230V 3~
ONLY FOR BELGIUM
400V 2N~
FOR NL ONLY
A B
C
Komentáře k této Příručce