ELECTRIC HEATING BELT
ELECTRIC HEATING BELT FOR INVERTER MODEL AMC 996 - 998 ONLY
In case of malfunction of the outdoor temperature sensor, both electric belts stop working. Under normal
conditions, operations is as follows:
1. When the outdoor temperature is -5° or less and the compressor does not start, the electric heating
belt on the compressor start; if the compressor is running or does not start but the outdoor
temperature is > -2°C, the electric heating belt does not start. If the compressor does not start and
the outdoor temperature is between -5°C and -2°C the electric heating belt on the compressor
maintains its current status.
2. When the outdoor temperature is less or equal to 3°C the electric condenser heating belt will work. If
the outdoor temperature is greater than 6°C it will not work. Between 3° and 6°C it maintains its
current status.