240-VOLT ELECTRICCOMPACT DRYERUse & Care GuideFor questions about features, operation/performanceparts, accessories or service, call: 1-800-253-13
103-wire connection: Power supply cordUse where local codes permit connecting cabinet-ground conductor to neutral wire.1. Loosen or remove center term
11Optional 3-wire connetionUse for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wir
12Plan Vent SystemTypical installations vent the dryer from the rear of the dryer.Alternate installations for close clearancesVenting systems come in
13The angled hood style (shown following) is acceptable.See the exhaust vent length chart that matches your hood type for the maximum vent lengths you
14Level DryerCheck levelness of dryer. Check levelness first side to side, then front to back.If dryer is not level, prop the dryer up using a wood bl
15DRYER USEStarting Your Dryer WARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS befor
16LoadingLoad clothes loosely into the dryer. Do not pack the dryer. Allow space for clothes to tumble freely. The following chart shows the maximum l
17DRYER CARECleaning the Dryer LocationKeep dryer area clear and free from items that would obstruct the flow of combustion and ventilation air.Cleani
18Removing Accumulated LintFrom Inside the Dryer CabinetLint should be removed every 2 years, or more often, depending on dryer usage. Cleaning should
19Stains on load or color change Was dryer fabric softener properly used?Add dryer fabric softener sheets at the beginning of the cycle. Fabric softe
2TABLE OF CONTENTSDRYER SAFETY...3INSTALLATION INSTRUCTIONS...
WHIRLPOOL®DRYER WARRANTYONE-YEAR FULL WARRANTYFor one year from the date of purchase, when this dryer is operated and maintained according to instruct
3DRYER SAFETYYou can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don'tfollow All
4INSTALLATION INSTRUCTIONSTools and PartsTools neededGather the required tools and parts before starting installation. Read and follow the safety inst
5Installation ClearancesThe location must be large enough to allow the dryer door to open fully.Dryer Dimensions*Most installations require a minimum
6Electrical RequirementsIt is your responsibility To contact a qualified electrical installer. To be sure that the electrical connection is adequate
7Electrical ConnectionPower Supply Cord1. Disconnect power.2. Remove the hold-down screw and terminal block cover. Direct Wire3. Assemble a ³⁄₄"
8Electrical Connection Options*If local codes do not permit the connection of a frame-grounding conductor to the neutral wire, go to “Optional 3-wire
94-wire connection: Direct Wire IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire con