7
Gas adjustments
Use pressure regulators that are suitable for the gas
pressure values indicated in the Product Description Sheet
supplied separately.
If the appliance is arranged for a type of gas different from that
available, it is necessary to change the injectors, adjust the
minimum flame, change the outlet connector.
Carry out the following operations to change the hob injectors:
remove the grills; remove the burners, the burner caps
(see Fig. 5); change the injector and replace it with one suitable
for the new type of gas (see table in separate Product Sheet).
Replace the gas calibration label with the new label included in the
injector bag.
Refit everything in reverse order, making sure to correctly fit the
burner cap on the burner.
Minimum for hob taps
To adjust the minimum flame, proceed as follows:
• Light the burner and turn the knob to minimum ; remove
the tap knob (Fig. 6). Insert a small screwdriver next to the tap
pin (Fig. 7).
Attention: in taps with security valve, the minimum adjusting
screws is placed outside the rod tap (fig. 7A).
Turn the adjustment screw anticlockwise to increase the flame,
or clockwise to decrease it. Adjustment is correct when the flame
is approx. 3 - 4 mm.
The adjustment screw must be completely screwed down for
butane/propane gas.
Make sure the flame does not go out when switching suddenly
from high to low flame and vice versa.
Refit the knob.
Fig. 6
Fig. 5
Fig. 7
Fig. 7A