91
ELECTRICAL CONNECTION AND SAFETY
For the electrical connection, make sure to follow the
instructions given below:
•
The earth wire must be connected to the earth terminal ( ).
If there is no approved earthed electrical outlet in the place
where the appliance is to be installed, immediately contact to
our Authorised Service.
•
The earthed electrical outlet must be close to the appliance.
Do not use extension cords.
•
The power cable must not touch hot parts of the product.
•
If the power cable is damaged, contact a Qualified Service
Centre. The cable must be replaced by the Authorised
Service.
•
An incorrect electrical connection could damage your
appliance. Such damage is not covered by the warranty.
•
The appliance is arranged for a 230 Volt power supply. If the
power supply voltage is different, immediately contact to our
authorised service.
The power cable must not touch hot parts of appliance.
Otherwise it may become damaged.
This situation could cause short circuiting.
The manufacturer declines any liability for damage and loss due to
failure to comply with the following safety regulations
If replacing the power cable, the new one must have the same
characteristics that are specified in this manual.
To replace the cable, proceed as follows:
•
open the terminal board box;
•
undo the cable fixing screw
A
;
•
loosen the screw contacts and replace the cable with one of
the same length, complying with the table in the section
“Electrical connection”;
•
the
Yellow/Green
earth wire must be connected to the
terminal and be approx. 20 mm longer than the line wires;
•
the
Blue
neutral wire must be connected to the terminal
marked with the letter
N
;
•
the live wire must be connected to the terminal marked with
the letter
L
.
A
Electrical Connection Diagram