Provision for room ventilation
This appliance is not connected to a fume exhaust device.
Therefore it must be installed and connected in compliance with
current installation regulations.
Particular attention must be paid to the applicable standards
concerning room ventilation.
Room ventilation
This appliance must only be installed and used in well-
ventilated rooms, in compliance with the current and local
regulations, with openings in the walls or with special ducts
enabling adequate natural or forced ventilation, and
ensuring the air necessary for correct combustion and air
change.
In particular, if there is only this gas appliance in the room, a hood
must be installed above it to ensure natural and direct extraction,
with a straight vertical duct of length equal to at least twice the
diameter and a minimum section of at least 100 cm
2
.
For the inlet of fresh air into the room, a similar opening of at least
100 cm
2
directly to the outside must be provided at a suitable
height from the floor so as not to be obstructed on the inside or
outside of the wall and not to hinder the correct combustion of
the burners and the regular extraction of vitiated air, and with a
height difference of at least 180 cm with respect to the outlet
opening.
The quantity of air necessary for combustion must not be less
than 2 m
3
/h for every kW of power (see total power in kW on the
appliance dataplate).
In all other cases, when there are other appliances in the same
room, or when direct natural ventilation is not possible and
indirect natural ventilation or forced ventilation is required,
contact a qualified specialist for carrying out installation and
preparing the ventilation system in strict compliance with the
current regulations.
Flues already used by other appliances must not be used for the
fume exhaust.
Air inlet section
min. 100 cm
2
Air outlet section
min. 100 cm
2
Air inlet section
min. 100 cm
2
Air inlet section
min. 100 cm
2
Electric fan
Cooker hood
flue