Whirlpool AKM 521/IX/01 Návod k použití Strana 21

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 24
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 20
To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws in accordance
with the thickness of the worktop (see the following gures).
Top 20 mm
Top 30-50 mm
ADJUSTMENT TO DIFFERENT TYPES OF GAS
This operation must be performed by a qualied technician.
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction.
The gas nozzles must be changed by After Sales Service or a qualied technician.
Nozzles not supplied with the appliance must be ordered from After Sales Service.
Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience difculty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner tap
if found to be faulty.
REPLACING THE INJECTORS (see the injector table in the Instruction)
Remove grids (A).
Extract burners (B).
Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector to
be replaced.
Replace it with the injector suitable for the new type of gas.
Re-assemble the injector in (D).
If you have a multiple crown burner use side spanner to replace the injector (E).
Before installing the hob, remember to afx the gas calibration plate supplied with the injectors in
such a way that it covers the existing information relating to gas calibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows:
tighten screw to reduce the ame height (-);
loosen screw to increase the ame height (+)
The adjustment must be performed with the tap in minimum gas setting position (small ame) .
The primary air of the burners does not need to be adjusted.
At this stage, light up the burners and turn the knobs from max position to minimum position to check ame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.
FR
REFERENCE TO LOCAL REGULATIONS
The installation and maintenance of the appliance must be carried out by a qualied skilled technician in accordance with the regulations in force, and in particular:
• Decree of 2 August 1977 - Technical and Safety Rules applicable to fuel gas and liqueed hydrocarbon installations located within residential buildings and outbuildings.
• Standard DTU P 45 - 204 - Gas installations (formerly DTU no. 61-1 - Gas installations April 1982 + supplement no. 1 of July 1984).
• Departmental Health Regulations - For appliances connected to the mains electricity supply.
• Standard NF C 15-100 - Low-voltage electrical installations - Standards.
BE
REFERENCE TO LOCAL REGULATIONS
The appliance is supplied with a 1/2” threaded conical end to be connected to the gas supply (according to ISO regulations ISO 7/1 RP 1/2).
The connection must be effected in accordance with standard NBN D 51-003 using rigid piping or in accordance with specications sheet A.R.G.B./03 using exible tubing.
The appliance must be installed complete with an AGB-approved stop valve.
AFTER-SALES SERVICE
Before calling the After-Sales Service, make sure you can give the following information:
- type of fault or problem;
- exact model (written on the label afxed to the instruction/warranty);
- service number that follows the word SERVICE on the rating plate under the hob and on the label afxed to instruction/warranty;
- your complete address and phone number.
If any repairs are required, please contact an authorised After-Sales Service, as indicated in the warranty.
WARNING