+3+E2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burnerInjector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
.xam.tar.nimRFEBWk
NATURAL GAS
(Methane) G20
Rapid 129 B3.00286 l/h0.800.60
17 20 25Semi-rapid971.65157 l/h0.450.35
Auxiliary74 B1.0095 l/h 0.35 0.30
NATURAL GAS
(Methane) G25
Rapid 129 B3.00332 l/h0.60
20 25 30Semi-rapid971.65183 l/h0.35
Auxiliary74 B1.00111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid863.00218 g/h0.60
20 28-30 35Semi-rapid651.65120 g/h0.35
Auxiliary501.0073 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid863.00214 g/h0.60
25 37 45Semi-rapid651.65118 g/h 0.35
Auxiliary501.00 71 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar1 R - 2 SR - 1 AUX 7.30 695 l/h9.52
G25 25 mbar 1 R - 2 SR - 1 AUX 7.30 809 l/h8.187
G30 28-30 mbar 1 R - 2 SR - 1 AUX 7.30 531 g/h 30.94
G31 37 mbar1 R - 2 SR - 1 AUX 7.30 521 g/h23.80
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Komentáře k této Příručce