INSTRUCTIONS FOR USE
MULTI SPLIT AIR CONDITIONER WITH
GAS R410a
PRECAUTIONS FOR USE
SPECIFICATIONS AND TECHNICAL DATA
INSTRUCTIONS FOR USE
HOW TO USE REMOTE CONTROL
CLEANING AND MAINTENANCE
TROUBLESHOOTING
INSTALLATION SERVICE - PRECAUTIONS
ON INSTALLATION
ELECTRICAL SAFETY REQUIREMENTS
INSTALLATION DIMENSION DRAWINGS
INSTALLING INDOOR UNIT
CHECKS AND TEST RUN AFTER INSTALLATION
ELECTRICAL CONNECTION
Thank you for selecting a Whirlpool air conditioner. For best results, please keep this Manual properly for
future reference.
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for
the environment and human health, which could otherwise be caused by inappropriate waste handling of this
product.
The symbol on the product, or on the documents accompanying the product, indicates that this
appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment.
Disposal must be carried out in accordance with local environmental regulations for waste disposal.
For more detailed information about treatment, recovery and recycling of this product, please contact your
local city office, your household waste disposal service or the shop where you purchased the product.
Zobrazit stránku 0
1 2 3 4 5 6 ... 21 22

Shrnutí obsahu

Strany 1 - INSTRUCTIONS FOR USE

25INSTRUCTIONS FOR USEMULTI SPLIT AIR CONDITIONER WITH GAS R410aPRECAUTIONS FOR USESPECIFICATIONS AND TECHNICAL DATAINSTRUCTIONS FOR USEHOW TO USE REM

Strany 2 - PRECAUTIONS FOR USE

34CLEANING AND MAINTENANCEIndoor unitWarning •Make sure to stop the unit and unplug it before cleaning your air conditioner. Otherwise you may risk el

Strany 3

35Checks before Seasonal Use1.Check the air inlet/outlet on indoor and outdoor units for any blocking. 2.Check the grounding cable for reliability. 3.

Strany 4

36TROUBLESHOOTINGIndoor unitWarning:Do not attempt to repair the air conditioner yourself. Incorrect repairs may cause electrocution or fire, so pleas

Strany 5 - Special Functions

37Malfunction CauseIndoor unit makes noise•The sound comes from the fan or compressor relay switching over (close/open).•Air conditioner may make nois

Strany 6 - HOW TO USE REMOTE CONTROL

38INSTALLATION SERVICE - PRECAUTIONS ON INSTALLATIONImportant Precaution1.The air-conditioning unit must be installed according to national wiring rul

Strany 7 - Remote Control

39ELECTRICAL SAFETY REQUIREMENTS1.The power supply must be of rated voltage with special circuitry for air-conditioning. The diameter of the power cor

Strany 8

40INSTALLATION DIMENSION DRAWINGSFrom the Wall From the ceiling Over 15 cm Over 15 cm Over 15 cm From the Wall Over 300cm Above the floorAirsuctionsid

Strany 9

41INSTALLING INDOOR UNIT Installing Wall-Mount Frame1.Level with plumb line or spirit level. As the drain outlet is on the left side, it is better for

Strany 10 - CLEANING AND MAINTENANCE

42Notes: If the connecting cable is not long enough, please contact the authorized service centre for a length of special cable. No joints are allowed

Strany 11 - Outdoor unit

43INSTALLING OUTDOOR UNITCable connection1.Remove the handle on the right side plate of the outdoor unit (one screw). 2.Remove the cable clamp, connec

Strany 12 - TROUBLESHOOTING

26PRECAUTIONS FOR USEWarning:•Make sure to insert the power plug securely. Insecure insertion of the plug may cause electrocution or fire. •Never unpl

Strany 13 - Malfunction Cause

44Installing the pipesInstall the drain fitting and the drain hose (for model with heat pump only)Condensation is produced and flows from the outdoor

Strany 14 - PRECAUTIONS ON INSTALLATION

45CHECKS AND TEST RUN AFTER INSTALLATION Check Items After InstallationTest Run 1. Preparation of Test Run •Do not switch on the power before all inst

Strany 15

46ELECTRICAL CONNECTION1) For Great Britain onlyWarning - this appliance must be earthedFuse replacementIf the mains lead of this appliance is fitted

Strany 16 - Over 240 cm

27SPECIFICATIONS AND TECHNICAL DATA1.The above data may change without notice. The data on the rating are accurate.2.When the unit is started again af

Strany 17 - Power Connection Cable

28INSTRUCTIONS FOR USEThe Principle and Special Functions of Cooling Mode Principle: The air conditioner absorbs heat from indoor air and discharges i

Strany 18 - Left rear

29Special FunctionsAbout 6th SENSEWhen 6th SENSE mode is selected, the setting temperature will not be displayed on the LCD, the unit automatically se

Strany 19 - INSTALLING OUTDOOR UNIT

30HOW TO USE REMOTE CONTROLOperating Guideline - General Procedures 1.After the main unit is connected to power, press the ON/OFF key on the remote co

Strany 20 - Installing the pipes

31UP/DOWNUP/DOWN KeyPress these two keys when in COOL, DRY, FAN or HEAT mode to set a temperature between 16 and 30 °C. The temperature of each mode c

Strany 21 - INSTALLATION

32CLOCKCLOCK keyPress to set present time and then flashes. Press or  to adjust the time numeral segment within 5 seconds, if you press this but

Strany 22 - ELECTRICAL CONNECTION

33Replacement of Remote Control Battery and Precautions 1.Gently press down on the battery cover and push in the direction of the arrow to remove, as

Komentáře k této Příručce

Žádné komentáře