Whirlpool Ultra Low Nox Příručka pro použití a péči

Procházejte online nebo si stáhněte Příručka pro použití a péči pro Ohřívače vody a bojlery Whirlpool Ultra Low Nox. Whirlpool Ultra Low Nox Use & care guide [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 32
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbors phone. Follow
the gas suppliers instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
INSTALLER:
AFFIX THESE INSTRUCTIONS TO OR ADJACENT
TO THE WATER HEATER.
OWNER:
RETAIN THESE INSTRUCTIONS AND WARRANTY
FOR FUTURE REFERENCE. RETAIN THE ORIGINAL
RECEIPT AS PROOF OF PURCHASE.
Table of Contents ...................................................... 2
319118-002
October 2010
Ultra Low Nox
Gas Water Heater
with the Flame Lock
®
Safety System
To obtain technical, warranty, or service assistance during or after
the installation of this water heater, visit our website at:
http://www.whirlpoolwaterheatersupport.com
or call toll free
1-877-817-6750
When calling for assistance, please have the following
information ready:
1. Model number
2. 7 digit product number
3. Serial number
4. Date of installation
5. Place of purchase
Installation
Instructions and
Use & Care Guide
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - Use & Care Guide

1Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.WHAT TO DO IF YOU SMELL GAS • Do

Strany 2 - WATER HEATER SAFETY

10Vent Pipe SystemThis water heater uses a non-direct, single-pipe vent system to remove exhaust gases created by the burning of fossil fuels. Air for

Strany 3 - Unpacking the Water Heater

11Chimney ConnectionIMPORTANT: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. The chimney

Strany 4 - Location Requirements

12Water System PipingPiping InstallationPiping, fittings, and valves should be installed according to the installation drawing (Figure 13). If the ind

Strany 5 - Clearances and Accessibility

13Please note the following: • The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, o

Strany 6 - Gas Supply

14Temperature and Pressure Relief ValveFor protection against excessive pressures and temperatures, a temperature and pressure relief valve must be in

Strany 7 - Ventilation

15Special ApplicationsCombination Space Heating/Potable Water SystemSome water heater models are equipped with inlet/outlet tappings for use with spac

Strany 8 - Confined Space

16Water Heater LocationWater heater location is important and can affect system performance. Please check the following:□ Installation area free of

Strany 9

17OPERATING YOUR WATER HEATERLighting InstructionsRead and understand these directions thoroughly before attempting to light or re-light the pilot. Ma

Strany 10 - Vent Connectors

18Burner FlamesInspect the burner flames through the viewport. Flames should be very small with a blue haze and small amounts of yellow or orange at t

Strany 11 - Vertical Exhaust Gas Vent

19Water Temperature RegulationThe thermostat is adjusted to the pilot position when it is shipped from the factory. Water temperature can be regulated

Strany 12 - Water System Piping

2Table Of ContentsWater Heater Safety ...1-2Installing Your Gas Water Heate

Strany 13

20Operating the Temperature Control SystemFigure 19B: Status CodesVACList of status codes are shownat top of gas control valve/thermostat.Water Temper

Strany 14 - Relief Valve

21Operational ConditionsCondensationMoisture from the products of combustion condenses on the tank surface and the outside jacket of the water heater

Strany 15 - Special Applications

22MAINTENANCE OF YOUR WATER HEATERDraining and FlushingIt is recommended that the tank be drained and flushed every 6 months to remove sediment which

Strany 16 - Installation Checklist

23Replacement PartsIMPORTANT: The following maintenance procedures are for the Flame Lock® Safety System components and should be performed by a quali

Strany 17 - Lighting Instructions

24Replacing the Pilot/Thermopile Assembly1. Remove the burner assembly as directed previously.2. Lift the retainer clip straight up from the back of

Strany 18 - Checking the Draft

25Check the door gasket for damage or imbedded debris 1. prior to installation.Inspect the viewport for damage and replace as required.2. Insert the b

Strany 19 - Water Temperature Regulation

26Removing and Replacing the Gas Control Valve/ThermostatRemoving the Gas Control Valve/Thermostat:1. Turn the gas control/temperature knob to the “

Strany 20 - Status Light Codes

27PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTIONPILOT WILL NOT LIGHT OR REMAIN LIT (continued)9. ECO switch open10. Pilot line or orifice clogged11. No

Strany 21 - Operational Conditions

28STATUS LIGHT CODE TROUBLESHOOTING CHART LED STATUS PROBLEM CORRECTIVE ACTION0 FLASHES (LED NOT LIT) Pilot light is not lit. Not enough power (milliv

Strany 22 - Maintenance

29PILOT LIGHT TROUBLESHOOTING CHART Have you bled all the air from the pilot tube and gas supply line?NOWhile repeatedly depressing the igniter button

Strany 23 - Replacement Parts

3INSTALLING YOUR GAS WATER HEATERImportant Information About This Water HeaterThis gas water heater was manufactured to voluntary safety standards to

Strany 24 - Flame-trap

30REPAIR PARTS ILLUSTRATION1234851011976Item No.Parts Description1 DRAFT HOOD2 REDUCER RING - SOME MODELS3 FLUE BAFFLE4 HEAT TRAP (COLD) - SOME MODELS

Strany 25 - Testing the Igniter System

31Listed Parts Kits and IllustrationsItem 12: Pilot assembly kit, which contains the pilot, electrode, and thermopile (Natural Gas) Item 13: Burner

Strany 26 - TROUBLESHOOTING CHART

32® Registered trademark/TM Trademark of Whirlpool, U.S.A. © 2010 Whirlpool Corporation. All rights reserved. Manufactured under license by American

Strany 27

4Location RequirementsThe Flame Lock® Safety System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your

Strany 28

5IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to t

Strany 29

6Gas SupplyGas RequirementsIMPORTANT: Read the data plate to be sure the water heater is made for the type of gas you will be using in your home. This

Strany 30 - REPAIR PARTS ILLUSTRATION

7Combustion Air Supply and VentilationIMPORTANT: Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to cor

Strany 31 - Item #12

8Unconfined SpaceA water heater in an unconfined space uses indoor air for combustion and requires at least 50 cubic feet for each 1,000 BTU/HR of the

Strany 32

9All Air from OutdoorsOutdoor fresh air can be provided to a confined area either directly or by the use of vertical and horizontal ducts. The fresh a

Komentáře k této Příručce